Identify the report
The linked Freedom Diagnostics certificate identifies AOD-9604 5 mg, lot AOD52609-144I, accession 2609170914, reported September 19, 2026. Keep those identifiers with the result.
Read the reported chemistry
The document reports confirmed identity by LC-MS, 99.87% HPLC-UV purity and 6.06 mg net content. These numbers refer to the submitted 5 mg sample. They do not establish the results for a different lot.
Use the original endotoxin wording
The document includes two endotoxin replicates marked Pass and lists an assay sensitivity of ≤0.05 EU/mL. Preserve the distinction between a pass result and a reported assay sensitivity instead of turning either into an unrelated microbiology claim.
Match your received material
The source listing also retains historical AOD9604 lots. Confirm which one will ship and compare the vial label with the corresponding report at receipt. The existence of this document is not a promise that every future shipment has this lot number.
Open the source record.
AOD52609-144I original certificate, reported 2026-09-19. The sample label is 5 mg, with 99.87% reported purity and 6.06 mg measured content.
Sources: Bluum AOD9604 listing; Bluum lot-report lookup. Product details checked November 10, 2026. For laboratory research only. Not for human or animal consumption, clinical or therapeutic use. Purchasers must be 21 or older.